Liebert Nfinity, 4 - 20 kVA On-Line UPS

Thumbnail

  • Single phase on-line UPS
  • Compact mini-tower configuration is ideal for tight spaces
  • Offers generator compatibility
  • Provides wide input voltage range for fewer transfers to battery

Overview

Overview

Liebert Nfinity on-line UPS is a scalable system, designed with N+x parallel redundancy to provide a fault-tolerant network of power protection. Its modular design was devised to provide easy, user-installed upgrades as power demands grow. Configurations can be cost-effectively upgraded without re-investing in a new system or installation.

Features & Benefits

Features & Benefits

Liebert Nfinity UPS is available in scalable 4-16kVA and 12-20kVA models, 60 Hz. Modules are scalable in 4kVA increments.

Flexibility:
  • Allows addition of battery capacity without increasing footprint.
  • Extends backup time up to 72 hours with additional battery cabinets.
  • Upgrades for capacity or redundancy without the expense or installation downtime associated with the purchase of a new UPS.
  • Enables greater system control with remote management software.
Higher Availability:
  • Offers hot-swappable power, battery, control and display modules, allowing installation or replacement without compromising power to the load.
  • Provides redundant components at critical points of UPS operation.
  • Allows maintenance to be performed without shutdown.
  • Offers emergency power-off capability.
  • Transfers seamlessly to and from the bypass source, with patent pending intelligent bypass technology.
  • Operates with a wider input voltage window for fewer transfers to battery, saving battery wear and tear.
  • Provides compatibility with backup generator — handles frequency variations and other power fluctuations that occur during generator operation.
  • Sustains 110% of the system’s rated load for an extended period of time — the highest overload capability of any system in its class.
Lowest Total Cost of Ownership:
  • Ships as a complete, fully tested system, ready for final connection.
  • Reduces maintenance costs with modular batteries, controls and power components.
  • Allows scalability to cost effectively invest in added capacity as it is needed.
  • Ships with batteries connected and charged, reducing installation time and costs.
Ideally Suited For:
  • Small-to-medium-sized data centers
  • Network closets
  • VoIP

Specifications

Specifications

Family Name Liebert Nfinity™, 4 - 20 kVA
Model Number 8 Bay 12 Bay

Power Rating

Rating, VA 4, 8, 12, 16kVA 4, 8, 12, 16, 20kVA
Rating, W 2.8, 5.6, 8.4, 11.2kW 2.8, 5.6, 8.4, 11.2, 14kW

Input AC Specifications

Phase 2 2
Power Factor >0.98 >0.98
Input Frequency, Hz 60 60
Frequency Range, Hz 40 - 70 40 - 70
Input Voltage 208/240 208/240

General Specifications

UPS Technology On-Line On-Line

Battery Specifications

Battery Test Type On-Line On-Line
Battery Technology VRLA VRLA

Output AC Specifications

Nominal Voltage 120/208 120/208
Output Waveform Sinewave Sinewave
Nominal Current, Amps 50 or 60 50 or 60

Communications

Communications Options SNMP/RS232 SNMP/RS232
Software and Cable Multilink SW & Serial Cable Multilink SW & Serial Cable

Physical Data

Unit Height, inches (mm) 40 (1,016) 54 (1,372)
Unit Width, inches (mm) 20 (508) 20 (508)
Unit Depth, inches (mm) 28 (711) 28 (711)

Environmental

Operating Temperature, Minimum °F (°C) 32 (0) 32 (0)
Operating Temperature, Maximum °F (°C) 104 (40) 104 (40)
Storage Temperature, Maximum °F (°C) 158 (70) 158 (70)
Relative Humidity 0% to 95%, Non Condensing 0% to 95%, Non Condensing
Operating Elevation, ft. (m) to 10,000 (3,000) to 10,000 (3,000)
Storage Elevation, ft. (m) to 30,000 (10,000) to 30,000 (10,000)
Sound Emission/Audible Noise < 62 dBA, at 1 meter < 62 dBA, at 1 meter
Cooling Fan Cooled Fan Cooled

Agency/Certification/Conformance

Agency Approval cUL Listed, FCC Part 15, Subpart B, Class A, UL 1778, UL Listed cUL Listed, FCC Part 15, Subpart B, Class A, UL 1778, UL Listed

Warranty

Standard 2 years 2 years
Extended Contact Liebert Global Services for additional service contract offerings on this product Contact Liebert Global Services for additional service contract offerings on this product

Other Photos

Other Photos

Thumbnail

 

Login

Login or register to access our Knowledge Center and other Technical Resources.

MiraNews

Mirapath is sponsoring The Data Center Summit, which is a partnership between the Silicon Valley Leadership Group, the California Energy Commission and the Lawrence Berkeley National Lab.

The Data Center Efficiency Summit is a one day forum that focuses on best practices and emerging technologies/applications that reduce data center costs and significantly increase efficiencies for both legacy and new construction.

Data Center operators present case studies on their efficiency projects accompanied by actual results and ROIs. Projects cover both IT optimization options and facilities related energy efficiency improvements that increase data center efficiencies.

Read more...