Products Data Center Infrastructure Management (DCIM)

SynapSoft™ 5.1 is a wireless data center monitoring and energy management solution. It provides real-time visibility, enhanced monitoring, alerts, and air mixing metrics which lead to significant energy savings. Data center managers utilize this 2009 Global Cleantech award winning solution to assess current operating conditions, identify opportunities and quantify efficiency improvements. It is a tool for continuous data center power and cooling optimization.


Quick links: Overview, Features and Benefits, Other Photos


Overview

This solution provides real-time, complete data center monitoring and visibility, allowing data center managers and facilities operators to make changes to their floor plan and energy use, while reducing their risk of downtime and reducing energy costs. This ground-breaking, green energy solution is comprised of a complete wireless hardware and software solution set designed specifically for large and global data centers (5K-10K sq. ft. minimum).

LiveImaging™ maps and movies highlight your specific environmental conditions using real-time data at multiple levels of the data center, and provide a visual display of actual examples of thermal air mixing, subfloor temperature and pressure differential, humidity and dew point.


Features and Benefits

  • LiveImaging™ reveals maps and movies of real-time temperature, humidity, pressure, dew point
  • Efficiency metrics for continuous optimization of data center power and cooling
  • Bi-directional SNMP and Modbus communication interfaces
  • Ease of installation and reconfigurability to support a dynamic data center
  • Power metering measures the cooling infrastructure and overall IT load
  • Branch Circuit Monitoring enables circuit-level monitoring to capture power by rack or cabinet for IT load balancing and capacity management
  • Allows for monitoring of circuit and rack-level power, leading to phase balancing and optimization of loading across PDU's

Data Center Efficiency Metrics
Our console calculates and display the following metrics, which have been developed in conjunction with the DOE:

Rack Cooling Index (RCI)TM/SM RCIHITM/SM and RCILOTM/SM
Measure of the cooling effectiveness of IT equipment racks to ASHRAE levels

Rack Moisture Index Hi/Lo
Measure of the moisture content of cooling air to IT equipment racks to ASHRAE levels

Recirculation Air Ratio (RA)
Measure of the temperature rise in the cold aisle from re-circulating hot discharge air

Bypass Air Ratio (BPA)
Measure of the temperature decrease in the cold aisle from re-circulation hot discharge air

Air Loss Ratio (ALR)
Measure of the CRAC/CRAH air flow wasted due to recirculation and by-pass air

Core Components

  • Sensor Instrumentation
  • Efficiency Consulting
  • Containment Services
  • Non-disruptive Installation
  • Service Agreement
  • Support Program
  • SynapSoft™ Data Center Application Suite
  • SynapSense™ Wireless Network
  • Alarm & Alert System
  • SynapSense™ Gateways
  • SynapSense™ Server
  • SynapSense™ Wireless Nodes