• Form Factor: 0U Vertical
  • Voltage: 208V
  • Amps: 20 Amps
  • Input Plug: Nema L6-20P
  • Output Plug: 20 x IEC C13

Quick links: Overview, Features and Benefits, Specifications, Other Photos, Ordering Details


Overview

Raritan's Dominion® PX Intelligent Remote Power Management Solutions help IT administrators improve uptime and staff productivity, save money and improve utilization of power resources.

With the Dominion PX:

  • Emergencies can be resolved with remote serial and TCP/IP access to outlet-level switching, improving MTTR.
  • Capacity planning is simplified with unit-level and outlet-level power utilization information.
  • Staff can gather detailed power information to improve uptime and productivity.
  • Travel costs and time can be saved with remote power cycling and monitoring.

Information provided by the Dominion PX — displayed at the strip via an LED display, and remotely through a Web browser — can be used to improve capacity planning through power consumption information for both the PDU and individual receptacle. Precise, outlet-level access and control allows users to reboot attached devices.

Whether used alone or integrated with other Raritan solutions, the intelligent Dominion PX offers secure access with 256-bit AES encryption and strong passwords. Dominion PX supports advanced authorization options including outlet-level permissions and LDAP/S, RADIUS and Active Directory®. Flexible management interfaces support HTTP, HTTPS, IPMI, SMASH-CLP, SSH, Telnet and SNMP, as well as user-configurable, outlet-level delays for power sequencing.

Dominion PX Remote Power Management Solutions can be integrated with the following Raritan solutions:

  • KVM switches: Dominion® KX II and Paragon® II
  • Secure console servers: Dominion SX
  • Centralized IT infrastructure management: CommandCenter® Secure Gateway

Features and Benefits

Features

Benefits

Power Distribution

Power Sequencing
(User Defined)

In the event the PX is reset, the outlets will be turned on in a user-defined sequence at user-defined intervals to prevent tripping circuit breakers due to in-rush currents. (Applies only to PX models that support switching.)

Receptacle Status Retention

In the event of a power outage, power is restored only to those receptacles that were on before the outage. For PX models that don't support switching, power will be restored to all outlets.

Circuit Breakers

The PX uses UL 489 circuit breakers instead of fuses in 30A/32A models or higher, meeting the newest safety standard for branch circuit protection (UL60950 third edition). This eliminates the need for spare fuses and the time to replace them. Also, in many cases, a certified/licensed electrician is required to replace a fuse, whereas circuit breakers can be reset by a user.

Power Monitoring

Power Metering

The PX enables users to measure power at the outlet level (RMS, apparent power), providing an accurate view of power consumption at both a server or PDU level.

Alerting

In case a threshold is exceeded, or a circuit breaker trips, the PX alerts the user via e-mail, SMS (via external gateway), audio alarm, and SNMP TRAPs, providing advanced warning before major incidents occur.

Overload Alarm

User-configurable current threshold provides audible and visual alarm on current overload, allowing the user to act immediately to prevent potential burnouts and interruption of services.

Environmental Monitoring

The PX supports external optional but fully integrated temperature and humidity sensors, providing early warning about hotspots or changes in cooling.

Seven-Segment LED Display

Shows actual current, voltage and circuit breaker status of the PDU for both the total strip and for individual receptacles.

Remote Access

IP Auto Configuration with DHCP, BOOTP

Easy setup and administration.

Flexible Remote Access Options

Users can access the PX through a variety of access protocols for switching (where supported), metering, data collection and monitoring:

  • Convenient HTML GUI
  • Server Management Interface (IPMI)
  • Network Management Interface (SNMP)
  • UNIX®-like console interface via serial connector or TELNET/SSH (compatible with SMASH server management)

Dynamic DNS Support

Users can access the PX over a connection with a dynamically assigned IP address - which corresponds to a single DNS name.

IPMI and SMASH CLP

The first and only PDU in the world that supports industry management standards: the Intelligent Platform Management Interface (IPMI) and the Distributed Management Task Force's (DMTF) Systems Management Architecture for Server Hardware (SMASH) CLP, providing a uniform way to manage both servers and the PDU.

Power Management

HTML User Interface

The PX's intuitive browser-based GUI enables remote energy management.

Outlet Grouping

When using PX models which support switching in a stand-alone mode over TCP/IP, users can define multiple outlets across multiple PDUs to function as a single virtual outlet. This is useful for powering down and rebooting servers with redundant power supplies.

Virtual Outlets

For PX models that support switching, outlets on multiple PX units can be grouped for ease of management and administration of servers.

Integration with Multiple Raritan Solutions

Simplified power control capabilities, power on/off/recycle, is available through Raritan's Dominion KXII, Dominion SX, Paragon® II, and CommandCenter® Secure Gateway 3.1.1 or higher, providing systems administrators access to power control via one­user interface.

Security

Up to 256-bit AES Encryption

The PX is the first and only PDU in the industry that supports 256-bit AES encryption.

SSL Certificate

Creating individual server side SSL certificates enhances the security level of PX.

Event Logging

Tracks user logins, logouts, and power activities for an audit trail to support regulatory compliance.

Local and Remote Authentication and Authorization

PX provides built-in support for standards-based authentication protocols, including LDAP/S, RADIUS, and Active Directory. When deployed in conjunction with other Raritan solutions, additional authentication schemes can be supported, including TACACS+, Kerberos, and SecureID.

User-Rights Per Outlet

An administrator can assign permissions on an outlet level to prevent unauthorized access.

Hardware Features

Vertical and Horizontal Rack Mount Models

PX units come in a choice of space-saving form factors for vertical and horizontal rack mounting. 1U and 2U units mount horizontally on standard racks. Zero U units mount vertically on rack frames.

Integration with Industry-Leading Racks

Easy integration and support for up to 5 different mounting positions in industry-leading racks.

Connections

Serial RJ-12 for environmental probes, RJ-45 for serial access/Power-CIM, RJ-45 Ethernet 10/100Base-T. Link status, network activity, and 10/100 status LED. Full support for full-duplex and 100Mbps operation.

Receptacle Status LED

Individual LED indicator at each receptacle allow for quick and easy status checks at the rack.

Flexibility of Connections

Simultaneous connection via Ethernet (TCP/IP) and serial ports for advanced applications and redundancy of connections.


Specifications

Input

  • Nominal voltage: 208-240V AC, single phase
  • Maximum line current per phase: 20A
  • Rated current: 16A
  • Load capacity: 3.3kVA
  • Frequency: 50-60 Hz
  • Plug type: NEMA L6-20P

Output

  • Nominal voltage: 208-240V AC
  • Maximum current draw: 20A
  • Switched receptacles: 20 x IEC C-13

Metering

  • Inlet: Voltage, current, power
  • Outlet: Voltage, current, power

Rack Environment Management

  • Optional temperature and humidity sensors (RJ-12 connector)

Interface and Protocol Support

  • RS-232 (RJ-45 connector)
  • 10-100 Mbps Ethernet (RJ-45 connector)
  • Authentication: Active Directory®, LDAP, RADIUS
  • Security: SSH, HTTPS, ACL, strong passwords, certificates, 256-bit AES encryption
  • SMASH CLP, IPMI
  • SNMP TRAPs, SETs, GETs, V2/V3
  • Web browser access

Mechanical

  • Rack space: Zero U
  • Mounting: Rack mount brackets included
  • Dimensions (WxDxH): 2.24" x 1.97" x 70.79"; 57 x 50 x 1798 mm
  • Weight: 11.2 lbs; 5.1 kg
  • Display/control panel: LED for current and voltage by outlet and total PDU
  • Line cord: 15 ft / 4.5 m (add 3.5"/88 mm (2U) to the height to allow for the line cord's radius of curvature)
  • LED power ON/OFF indicators at each outlet
  • Color: Black powder coat
  • Shipping dimensions (WxDxH):
  • Shipping weight:

Environmental requirements

  • Operating temperature: 5-45 degrees Celsius
  • Humidity: 5-90% RH non-condensing
  • Altitude: 10,000 feet

Approvals

  • FCC Part 15, A; cTUVus which is fully compliant with UL 60950-1 Rev. 3; EN 55022, Class A; EN 55024; EN 60950-1; CE mark; C-Tick and PSE
  • RoHS/WEEE compliant

Warranty

  • Two years, 100% parts and workmanship

Other Photos


Ordering Details

Main Units

Part Number
Description
MSRP
DPCS20A-20L6 Zero U vertical PDU with 20 x IEC C-13 outlets, 208V AC, 20A, 3.3kVA, NEMA locking plug: L6-20P. Ethernet and serial connections. $1,149.00

Accessories

Part Number
Description
MSRP
WARDPCS20A-20L6/1 1-Yr Extended Warranty for DPCS20A-20L6 Gold $230.00
WARDPCS20A-20L6/2 2-Yr Extended Warranty for DPCS20A-20L6 Platinum $287.00