Switched
Server Technology
Sever Tech Switched CDU CW-8H
Quick links: Overview, Features and Benefits, Specifications, Other Photos, Ordering Details
The Switched Cabinet PDU 8H combines remote configuration and management with power distribution, power monitoring and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups. It's horizontal configuration offers the perfect solution for small or cramped cabinets where one or two vertical power distribution units will not fit.
Only the Switched Cabinet PDU products provide the flexibility needed for all datacenters and remote sites; including support for 20-amp or 30-amp power input; 100-120V, 208-240V or European 230V configuration; UL 60950-1 branch circuit protection; EN 60950-1:2001, SSL & SSH security; and SNMP-based input current monitoring. For cabinets with low-density servers, this cabinet distribution unit delivers unparalleled solutions.
Individual or group outlet remote power control to cycle power and reboot any selected server(s) or other network device(s). Use TCP/IP (HTTP, HTTPS, SSH, Telnet, SNMP) or RS-232 to communicate with each Sentry Cabinet PDU and rectify locked-up network devices. Assign outlets to a group for control of dual-power supply servers and other gear with a single command. Create an unlimited number of groups with any combination of outlets associated to each group. Reduce Mean Time to Repair (MTTR) a failing server by controlling individual power outlet receptacles to reboot any selected server or other device.
Use the Sentry Web interface to configure each unit, including network settings, outlet naming & grouping, SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to control individual or group outlets and monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.
The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information and control power for the individual outlets. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, closed contacts (cabinet doors open/close), as well as notification of any time an outlet status is changed (on/off).
Connect an Expansion Cabinet PDU to any Switched Cabinet PDU to control two power input circuits and manage outlets (individual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.
A horizontal enclosure that occupies 1U horizontal rack space in the equipment cabinet. It typically mounts on the back of a 19 or 23 inch rack.
Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device. Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers. Sentry supports SSLv3/TLSv1.
Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.
Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.
The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
- Microsoft Active Directory (MSAD)
- Novell eDirectory (eDir)
- Open LDAP
Individual input current monitoring ("Load Sense") provides real-time power measurement of the load in amps on each power inlet, accessible via firmware interface.
Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.
16 or 20 Amp Power Input Support
16 or 20-Amp Power Input Support - IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX).
30 or 32 Amp Power Input Support
30 or 32 Amp Power Input Support provides hard-wired 10' cord and appropriate L5-30 or L6-30 plug type.
Use the firmware interface (Web or serial) to edit individual outlet receptacles. Identify each receptacle with the device's serial number, IP address, asset allocation #, department or any other method to individually name outlets.
| Sentry Cabinet PDU Specifications | |||||
| Item # | Available Input Voltages |
Rated Amperage | Available Input Cord | Outlets | Dimensions (L x W x D) |
| CW-8H | |||||
| CW-8H1-C20M CX-8H1-C20M* |
100-120V 50/60Hz |
20A | IEC 60320/C20 Power Inlet |
(8) NEMA 5-20R | 1.75" x 17.0" x 7.0" (44x431.8x177.8mm) |
| CW-8H1-L30M CX-8H1-C20M* |
100-120V 50/60Hz |
30A | NEMA L5-30P Cord Set, 10 ft (3m) |
(8) NEMA 5-20R | 1.75" x 17.0" x 7.0" (44x431.8x177.8mm) |
| CW-8H2-C20M CX-8H2-C20M* |
208-240V 60Hz |
20A | IEC 60320/C20 Power Inlet |
(8) IEC 60320/C13 | 1.75" x 17.0" x 7.0" (44x431.8x177.8mm) |
| CW-8H2-L30M CX-8H2-L30M* |
208-240V 60Hz |
30A | NEMA L6-30P Cord Set, 10 ft (3m) |
(8) IEC 60320/C13 | 1.75" x 17.0" x 7.0" (44x431.8x177.8mm) |
| CW-8HE-C20M CX-8HE-C20M* |
230V 50/60Hz |
16A | IEC 60320/C20 Power Inlet |
(8) IEC 60320/C13 | 1.75" x 17.0" x 7.0" (44x431.8x177.8mm) |
| CW-8HE-P32M CX-8HE-P32M* |
230V 50/60Hz |
32A | IEC 60309 Cord Set, 10 ft (3m) |
(8) IEC 60320/C13 | 1.75" x 17.0" x 7.0" (44x431.8x177.8mm) |
| * CX refers to the Expansion Module | |||||
| Power Cord Options | |||||
| > PTCORD-1 IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock) 10' > PTCORD-2 IEC 60320/C19 - Schuko 10' > PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10' > PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10' > PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10' > PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10' > PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10' > PT-ADP-C19 Cable mount IEC 60320/C19 Connector |
|||||