The Direct PDU power strip is for IT administrators who need a simple and cost-effective way to remotely manage the power requirements of their IT infrastructure.

The Direct PDU power strips are designed for small to midsized businesses and have an on-board web interface for direct access over any IP network. Other features include individual power on/off control, power consumption metering and overload protection. The power strip has built-in alarms to notify the administrator when user-defined thresholds are reached via simple network management protocol (SNMP) traps and e-mail notification. The Direct_PDU power strip is available in 8- and 16-port vertical mount (0U) and 8-port horizontal mount (1U) units.

Quick links: Overview, Features and Benefits, Specifications, Other Photos


Overview

Easy Manageability
The Avocent Direct PDU power strip provides a single, secure, browser-based interface to remotely manage the power requirements of your IT environment. Remotely power on/off unresponsive servers and data center equipment and monitor multiple Direct PDU power strips. Data center administrators are warned when current levels exceed user-defined thresholds, via audible alarms and alerts (SNMP and e-mail). Direct PDU power strip manageability is made easier with utility software.

High Availability
The Direct PDU power strip helps data center administrators manage all the power needs for their infrastructure at any time, from anywhere, over an IP network. The Direct PDU power strip prevents current overload by turning on power outlets in sequence and protects attached devices from power source overloads, surges and spikes. Audible and visual alerts, when user-defined thresholds are reached, enable administrators to minimize interruptions and increase uptime.

Lower Operational Costs and Increased Productivity
Effective power management reduces IT operational costs and risks while increasing IT asset and personnel productivity. The ability to turn on/off power to individual outlets remotely saves IT administrators from expensive trips back to the data center and unnecessary downtime. The Direct PDU power strip current meter and overcurrent alarm prevents power overloads and protects equipment from damaging power surges, reducing downtime and data loss due to power overloads, helping to maintain system availability.

Direct PDU Quick Facts
  • Monitor and manage power requirements of IT infrastructure
  • Direct access via on-board web interface
  • Individual power On/Off control
  • Built-in, user definable alarm and notification capabilities

Avocent Direct PDU's are available in the following configurations:

DPDU101 8-port PDU (vertical), 15A, 115V, NEMA 5-15p inlet, NEMA 5-15/20r outlets
DPDU102 16-port PDU (vertical), 20A, 115V, NEMA 5-20p inlet, NEMA 5-15/20r outlets
DPDU103 8-port PDU (horizontal), 15A, 115V, NEMA 5-15p inlet, NEMA 5-15/20r outlets
DPDU201 8-port PDU (vertical), 16A, 230V, IEC 320 inlet, C13r outlets
DPDU202 16-port PDU (vertical), 16A, 230V, IEC 320 inlet, C13r outlets
DPDU203 8-port PDU (horizontal), 16A, 230V, IEC 320 inlet, C13r outlets

Features and Benefits

Feature
Benefit
Built in on board web interface for management Convenient screen for easy management of outlets and configuration of SNMP and e-mail alerts
Independent control of each power port Ability to remotely power ON/OFF unresponsive servers and other IT equipment
Current meter & over current alarm Displays the power consumption of the power strip and alerts if user defined thresholds are exceeded
SNMP & E-mail notification Supports simple network management protocol (SNMP) and provides MIBs (management information base) for network management systems. Sends e-mails and trap information when user defined power consumption thresholds are met
Utility software included Monitoring multiple Direct_PDU power strips from a single interface
Power on sequence Prevents current overload by turning on the power script outlets in sequence when connected to a power source

Built-in circuit breaker

Provides protection to the attached devices from power source overloads

10/100Base-T Ethernet port

Access from anywhere via an IP network

LED on each port for visual status

Visual confirmation that each port is powered on or off.

Horizontal (1U) and vertical (0U) mounting options

Fits any server room rack deployment option


Specifications

Interfaces
Serial Port: N
Network Port: 10/100
Physical
Mounting: Vertical
Width: 49.02 in (124.51 cm)
Depth: 1.74 in (4.42 cm)
Height: 2.21 in (5.61 cm)
Weight: 8.4 lb (3.82 kg)
Environmental
Operating Temperature: Fahrenheit 32 ~ 104
Celsius 0 ~ 40
Storage Temperature: Fahrenheit 5 ~ 122
Celsius -15 ~ 50
Certifications
FCC, UL, cUL, CE, C-Tick