OpenGear
OpenGear IM4200
The IM4200 advanced console server is an out of band management solution for serial console ports, servers, virtual servers, service processors, UPS & PDU's, environmental monitoring and more. The IM4200 family of advanced console servers enables system administrators to securely access and control their data centers and networks from anywhere in the world.
Quick links: Overview, Features & Benefits, Specifications, Other Photos, Ordering Details
IM4200 Advanced Console Servers
Security
The IM4200 family of advanced console servers are built with security in mind, features such as in-built enterprise class firewall, FIPS 140-2 module, SSH v2, SSLv3 Ciphers, OpenVPN, IP Sec, Radius SecureID, IP Filtering and per port access list to give greater control over security to vital IT assets in the datacenter.
Console Management Features
The IM4200 is available in 8, 16 and 48 Port Models with three pinout options including Cisco compatible RJ45 ports for easy, quick installation. Features such as 16gb flash memory for offline logs, TFTP storage for running configurations, embedded AJAX terminal, pattern-match alerting and event notification help reduce downtime and expidite problem resolution. Powered by a robust Linux core, the IM4200 open source platform enables users to embed custom scripts, custom alerts and embed security agents.
Out-Of-Band Management
The IM4200 is equipped with a built in modem for dial-in, dial-back and heart beat monitor for automatic failover. We also support broadband failover and 3G cellular out of band access. The IM4200 is also equipped with the ability to "call home" from behind a firewall to our CMS/VCMS management platform. This unique ability gives systems administrators the ability to monitor, access and manage all downstream console servers and attached devices from one single screen.
Power Monitoring and Management
Opengear console servers are outfitted with a vendor neutral toolset to control the widest selection of third party PDU and UPS devices available on the market. The IM4200 is embedded with both Network UPS Tools and PowerMan to manage both serial and snmp based UPS systems and switched PDU's. Our power management and monitoring abilities include extensive alerting, power event notification, graceful shutdowns, ping detect reboots, DC line voltage and embedded hotkey for switched PDU's.
| High Availability |
|
| Security and Authentication |
|
| Serial Console Port Management |
|
| LAN Console Port Management |
|
| Power Management |
|
| System Management |
|
| Accessibility |
|
| Other Protocols Supported |
|
| Upgrades |
|
| Operating System |
|
| Connectors | 8, 16 or 48 RJ-45 RS-232 serial ports (2400 to 230,400bps) 1 DB-9 RS-232 local console and modem serial port (2400 to 115,200 bps) 1 RJ-11 V92 modem port 2 RJ-45 10/100Base-T Ethernet port 3 USB port |
| Power | Internal dual socket universal 100-240V AC, or Internal dual +/- 36V to 72V DC Power consumption less than 30W |
| Dimensions | 17 x 12.3 x 1.75 in (44 x 31.3 x 4.5 cm) 1RU with rack mounts |
| Environmental | Ambient operating temperature: 5°C to 50°C (41°F to 122°F) Non operating storage temperature: -30°C to +60°C (-20°F to +140°F) Humidity: 5% to 90% |
| Emissions | FCC Part 15 Subpart B Class A Radiated Emissions 30MHz – 1000MHz ICES-003 Issue 4 February 2004 Class A Radiated Emissions 30MHz – 1000MHz AS/NZS CISPR 22: 2004 Class A Radiated Emissions 30MHz – 1000MHz EN55022: 1998 + A1: 2000 + A2: 2003 Class A Radiated Emissions 30MHz – 1000MHz |
| Immunity | EN55024: 1998 +A1: 2001 +A2: 2003 IEC61000-4-2: 1995 ESD 8kV Air Discharge (Direct), 4kV Contact Discharge (Direct/Indirect) IEC61000-4-3: 1995 Radiated Immunity 3.0V/m, 1KHz AM Sine Wave at 80% IEC61000-4-4: 1995 EFT/Burst 1.0kV Power Lines, 0.5kV I/O Lines IEC61000-4-5: 1995 Surge Immunity 1.0kV Common Mode, 1.0 kV Differential Mode IEC61000-4-6: 1996 Conducted Immunity 3.0 Vrms, 80% AM Modulated (1KHz) IEC61000-4-11: 1994 Voltage Dips and Interrupts (>95%,0.5 periods), (30%,25 periods), (>95%,250 periods) |
| Isolation | Serial Port: 4 kV ESD protection on RS232 and RS422/485 transceivers Ethernet Port: 1500 VAC isolation shielded with shield connected to chassis ground for signal integrity and ESD protection |
| Other Agency Approvals | CE UL 1950 TUV C-Tick RoHS compliant NERC CIP Cyber Security compliant FIPS 140-2 Validated Module Certificate #1051 |
| CPU | 166MHz ARM (Micrel KS8695P) |
| Memory | 64MB SDRAM 16MB Embedded Flash 16 Gigabytes USB Flash |
| Operating System | Linux with source code access Custom development kit |
| 48 Port Units | Part Number |
| Classic Pinout | |
| IM4248-2-DAC-X0-US Dual AC power supplies, Classic Pinout |
IM4248-2-DAC-X0-US |
| IM4248-2-DDC-X0 Dual DC power supplies, Classic Pinout |
IM4248-2-DDC-X0 |
| Cyclades Pinout Units | |
| IM4248-2-DAC-X1-US Dual AC power supplies, Cyclades Pinout |
IM4248-2-DAC-X1-US |
| IM4248-2-DDC-X1 Dual DC power supplies, Cyclades Pinout |
IM4248-2-DDC-X1 |
| Cisco Pinout Units | |
| IM4248-2-DAC-X2-US Dual AC power supplies, Cisco Pinout |
IM4248-2-DAC-X2-US |
| IM4248-2-DDC-X2 Dual DC power supplies, Cisco Pinout |
IM4248-2-DDC-X2 |
| IM4248-2-DAC-X2-G-US Dual AC power supplies, Cisco Pinout, cellular 3G GSM |
IM4248-2-DAC-X2-G-US |
| IM4248-2-DAC-X2-GV-US Dual DC power supplies, Cisco Pinout, cellular Verizon CDMA EV-DO |
IM4248-2-DAC-X2-GV-US |
| 32 Port Units | Part Number |
| Classic Pinout | |
| IM4232-2-DAC-X0-US Dual AC power supplies, Classic Pinout |
IM4232-2-DAC-X0-US |
| IM4232-2-DDC-X0 Dual DC power supplies, Classic Pinout |
IM4232-2-DDC-X0 |
| Cyclades Pinout Units | |
| IM4232-2-DAC-X1-US Dual AC power supplies, Cyclades Pinout |
IM4232-2-DAC-X1-US |
| IM4232-2-DDC-X1 Dual DC power supplies, Cyclades Pinout |
IM4232-2-DDC-X1 |
| Cisco Pinout Units | |
| IM4232-2-DAC-X2-US Dual AC power supplies, Cisco Pinout |
IM4232-2-DAC-X2-US |
| IM4232-2-DDC-X2 Dual DC power supplies, Cisco Pinout |
IM4232-2-DDC-X2 |
| IM4232-2-DAC-X2-G-US Dual AC power supplies, Cisco Pinout, cellular 3G GSM |
IM4232-2-DAC-X2-G-US |
| IM4232-2-DAC-X2-GV-US Dual AC power supplies, Cisco Pinout, cellular Verizon CDMA EV-DO |
IM4232-2-DAC-X2-GV-US |
| 16 Port Units | Part Number |
| Classic Pinout Units | |
| IM4216-2-DAC-X0-US Dual AC power supplies, Classic Pinout |
IM4216-2-DAC-X0-US |
| IM4216-2-DDC-X0 Dual DC power supplies, Classic Pinout |
IM4216-2-DDC-X0 |
| Cyclades Pinout Units | |
| IM4216-2-DAC-X1-US Dual AC power supplies, Cyclades Pinout |
IM4216-2-DAC-X1-US |
| IM4216-2-DDC-X1 Dual DC power supplies, Cyclades Pinout |
IM4216-2-DDC-X1 |
| Cisco Pinout Units | |
| IM4216-2-DAC-X2-US Dual AC power supplies, Cisco Pinout |
IM4216-2-DAC-X2-US |
| IM4216-2-DDC-X2 Dual DC power supplies, Cisco Pinout |
IM4216-2-DDC-X2 |
| IM4216-2-DAC-X2-G-US Dual AC power supplies, Cisco Pinout, cellular 3G GSM |
IM4216-2-DAC-X2-G-US |
| IM4216-2-DAC-X2-GV-US Dual DC power supplies, Cisco Pinout, cellular Verizon CDMA EV-DO |
IM4216-2-DAC-X2-GV-US |
| 8 Port Units | Part Number |
| Classic Pinout Units | |
| IM4208-2-DAC-X0-US Dual AC power supplies, Classic Pinout |
IM4208-2-DAC-X0-US |
| IM4208-2-DDC-X0 Dual DC power supplies, Classic Pinout |
IM4208-2-DDC-X0 |
| Cyclades Pinout Units | |
| IM4208-2-DAC-X1-US Dual AC power supplies, Cyclades Pinout |
IM4208-2-DAC-X1-US |
| IM4208-2-DDC-X1 Dual DC power supplies, Cyclades Pinout |
IM4208-2-DDC-X1 |
| Cisco Pinout Units | |
| IM4208-2-DAC-X2-US Dual AC power supplies, Cisco Pinout |
IM4208-2-DAC-X2-US |
| IM4208-2-DDC-X2 Dual DC power supplies, Cisco Pinout |
IM4208-2-DDC-X2 |
| IM4208-2-DAC-X2-G-US Dual AC power supplies, Cisco Pinout, cellular 3G GSM |
IM4208-2-DAC-X2-G-US |
| IM4208-2-DAC-X2-GV-US Dual DC power supplies, Cisco Pinout, cellular Verizon CDMA EV-DO |
IM4208-2-DAC-X2-GV-US |
| Adapters for Classic Pinout (-X0) | Part Number |
| DB9F to RJ45 Straight adapter | 319000 |
| DB9F to RJ45 X-Over adapter | 319001 |
| DB25M to RJ45 Straight adapter | 319002 |
| DB25M to RJ45 X-Over adapter | 319003 |
| DB9M to RJ45 Straight adapter | 319004 |
| DB25F to RJ45 X-Over adapter | 319005 |
| 5ft CAT5 RJ45 to RJ45 cable | 440016 |
| RJ45 Plug to RJ45 Jack adaptor for Cisco/Sun | 449016 |
| RJ-45 plug to RJ-45 Jack adapter for Rackable Systems | 449017 |
| Adapters For Cisco Pinout (-X2) | Part Number |
| DB9F to RJ45 Straight adapter | 319014 |
| DB9F to RJ45 X-Over adapter | 319015 |
| DB9M to RJ45 Straight adapter | 319016 |
| Adapters For Cyclades Pinout (-X1) | Part Number |
| DB9F to RJ45 Straight adapter | 319017 |
| DB9F to RJ45 X-Over adapter | 319018 |
| DB9M to RJ45 Straight adapter | 319019 |
| Warranty and Support | Term |
| Standard warranty cover | 4-year, Pre-Paid |
| Extended warranty cover | 1-year, Pre-Paid |